Ši svetainė naudoja slapukus („cookies“), norint suteikti kokybiškesnes paslaugas. Likdami svetainėje sutinkate su šia politika.
Prekių grupės

Prekių kodai

KodasPavadinimasAprašymasGamintojas
DAT 5023IAC/DP.D.S series temperaure and signal convertersDip switch configurable din rail converter for AC current. Input : 0...40A, 0...50A, 0...60A. Configurable output : V or mA. Power supply 18...30Vdc. Reverse polarity protection 60Vdc max. Galvanic insulation : Power supply // input // output : 2000Vac, 50Hz, 1 min.Datexel
DAT 5023IDC/AP.D.S series temperaure and signal convertersDip switch configurable din rail converter for DC current. Input : 0...5A, 0...10A. Configurable output : V or mA. Power supply 18...30Vdc. Reverse polarity protection 60Vdc max. Galvanic insulation : Power supply // input // output : 2000Vac, 50Hz, 1 min.Datexel
DAT 5023IDC/DP.D.S series temperaure and signal convertersDip switch configurable din rail converter for DC current. Input : 0...40A, 0...50A, 0...60A. Configurable output : V or mA. Power supply 18...30Vdc. Reverse polarity protection 60Vdc max. Galvanic insulation : Power supply // input // output : 2000Vac, 50Hz, 1 min.Datexel
DAT 5022P.D.S series temperaure and signal convertersDip switch configurable din rail splitter, input : V, mA. Configurable output : V or mA. Power supply 18...32Vdc. Reverse polarity protection 60Vdc max. Galvanic insulation : power supply // input // output : 1500Vac, 50Hz, 1 min.Datexel
DAT 5023IDC/BP.D.S series temperaure and signal convertersDip switch configurable din rail converter for DC current. Input : 0...20A, 0...25A, 0...30A. Configurable output : V or mA. Power supply 18...30Vdc. Reverse polarity protection 60Vdc max. Galvanic insulation : Power supply // input // output : 2000Vac, 50Hz, 1 min.Datexel
DAT 5021P.D.S series temperaure and signal convertersDin rail dip switch configurable converter, input : V, mA. Power supply 18...32Vdc. Reverse polarity protection 60Vdc max. Configurable output : Voltage or Current. Galvanic insulation : Power supply // Input // Output : 1500Vac, 50Hz, 1 min.Datexel
DAT 2045P.D.S series temperaure and signal convertersNot insulated, not linearized din rail dip switch configurable transmitter TC input : J,K,R,S,T. Power supply 10...30Vdc (loop powered). Reverse polarity protection 60Vdc max. Output 4...20mADatexel
DAT 2145P.D.S series temperaure and signal convertersNot insulated, not linearized dip switch configurable din rail converter. Input : TC type: J,K,R,S,T. Power supply 10...30Vdc. Reverse polarity protection 60Vdc max. Configurable output : 0/4...20mA ; 0...10 V.Datexel
DAT 5020P.D.S series temperaure and signal convertersDin rail dip switch configurable converter, input : mV, V, mA, Potentiometer. Power supply 18...32Vdc. Reverse polarity protection 60Vdc max. Configurable output Voltage or current. Galvanic insulation : power supply // input // output : 2000Vac, 50Hz.Datexel
DAT 2166P.D.S series temperaure and signal convertersDouble channel not insulated dip switch configurable din rail converter. Input Pt100 2,3 wires. Power supply 10...30Vdc. Reverse polarity protection 60Vdc max. Configurable double output : 0/4...20mA ; 0...10 VDatexel
DAT 2061P.D.S series temperaure and signal convertersDip switch configurable din rail converter. Input Pt100 2,3 wires. Power supply 18...30Vdc. Reverse polarity protection 60Vdc max. Output 0/4...20mA , 0...10 V. Galvanic insulation :Power supply // Input, Output : 1500Vac, 50Hz. 1 min.Datexel
DAT 2066P.D.S series temperaure and signal convertersDouble channel not insulated dip switch configurable din rail transmitter. 2 x Pt100 2,3 wires inputs . Power supply 10...30Vdc (loop powered). Reverse polarity protection 60Vdc max. 2 x 4...20mA outputs.Datexel
DAT 2165P.D.S series temperaure and signal convertersNot insulated dip switch configurable din rail converter. Input Pt100 2,3 wires. Power supply 10...30Vdc. Reverse polarity protection 60Vdc max. Configurable output : 0/4...20mA ; 0...10 V.Datexel
DAT 2065P.D.S series temperaure and signal convertersNot insulated dip switch configurable din rail transmitter. Input Pt100 2,3 wires. Power supply 10...30Vdc (loop powered). Reverse polarity protection 60Vdc max. Output 4...20mA.Datexel
DAT 1065ISSMART ATEX series transmitters and convertersInsulated Intrinsically Safe Universal PC configurable IN HEAD transmitter. Input: mV, Resistance 2,3,4 wire, RTD 2,3,4 wire (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power Supply 11...30Vdc (loop powered). Output : 4...20mA. Version with 2000Vac (input // output) galvanic insulation. Approved ATEX 94/9/EC , Protection Mode : II 1 G Ex ia II C. (T5: -20 +70 °C; T6: -20 + 55 °C)Datexel
DAT 1065IS/HTSMART ATEX series transmitters and convertersInsulated Intrinsically Safe Universal PC configurable IN HEAD transmitter. Input: mV, Resistance 2,3,4 wire, RTD 2,3,4 wire (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power Supply 11...30Vdc (loop powered). Output : 4...20mA. Version with 2000Vac (input // output) galvanic insulation. Approved ATEX 94/9/EC , Protection Mode : II 1 G Ex ia II C. (T4: -20 + 85 °C; T5: -20 +70 °C; T6: -20 + 55 °C).Datexel
DAT 1015IS/HTSMART ATEX series transmitters and convertersNot insulated Intrinsically Safe Universal PC configurable IN HEAD transmitter. Input: mV, Resistance 2,3,4 wire, RTD 2,3,4 wire (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power Supply 11...30Vdc (loop powered). Approved ATEX94/9/EC directive. Protection mode : II 1G Ex ia II C. (T4: -20 + 85 °C; T5: -20 +70 °C; T6: -20 + 55 °C)Datexel
DAT 1015ISSMART ATEX series transmitters and convertersNot insulated Intrinsically Safe Universal PC configurable IN HEAD transmitter. Input: mV, Resistance 2,3,4 wire, RTD 2,3,4 wire (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power Supply 11...30Vdc (loop powered).Output : 4...20mA. Approved ATEX 94/9/EC directive. Protection mode : II 1 G Ex ia II C. (T5: -20 +70 °C, T6: -20 + 55 °C)Datexel
DAT 5030IS/BSMART ATEX series transmitters and convertersDouble Channel Repeater/Supply for current loop (active or passive). Signal input : configurable from 0 to 20mA, or from 4 to 20mA. Power supply 20...30Vdc. Reverse polarity protection 60Vdc max. Approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 5030IS/BHSMART ATEX series transmitters and convertersDouble Channel Hart Compatible Repeater/Supply for current loop (active or passive). Signal input : configurable from 0 to 20mA, or from 4 to 20mA. Power supply 20...30Vdc. Reverse polarity protection 60Vdc max. Approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 1010ISSMART ATEX series transmitters and convertersNot insulated Intrinsically Safe PC configurable IN HEAD transmitter. RTD, Resistance, mV and Potentiometer Input. Power supply 11...30Vdc (loop powered). Output 4...20mA. Approved ATEX94/9/EC directive. Protection mode : II 1G Ex ia II C. (T5:-20 + 70 °C, T6: -20 + 55 °C).Datexel
DAT 1010IS/HTSMART ATEX series transmitters and convertersNot insulated Intrinsically Safe PC configurable IN HEAD transmitter. RTD, Resistance, mV and Potentiometer Input. Power supply 11...30Vdc (loop powered). Output 4...20mA. Approved ATEX94/9/EC directive. Protection mode : II 1G Ex ia II C. (T4: -20 + 85 °C; T5: -20 +70 °C; T6: -20 + 55 °C)Datexel
DAT 5030IS/ASMART ATEX series transmitters and convertersSingle Channel Repeater/Supply for current loop (active or passive). Signal input : configurable from 0 to 20mA, or from 4 to 20mA. Power supply 20...30Vdc. Reverse polarity protection 60Vdc max. Intrinsically safe version approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 5030IS/AHSMART ATEX series transmitters and convertersSingle Channel Hart Compatible Repeater/Supply for current loop (active or passive). Signal input : configurable from 0 to 20mA, or from 4 to 20mA. Power supply 20...30Vdc. Reverse polarity protection 60Vdc max. Approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 4235IS/CSMART ATEX series transmitters and convertersDin Rail universal PC configuration Signal Converter. Input : mV, V, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power supply 20...30Vdc. Reverse polarity protection : 60Vdc max. Output : 0/1...10V, 0/4...20mA. Trip amplifier:n° 2 relays SPDT (2A, 250Vdc) (2A, 30Vdc). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz., 1 min. Approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 4235IS/BSMART ATEX series transmitters and convertersDin Rail Trip Amplifier. Input : mV, V, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power supply 20...30Vdc. Reverse polarity protection : 60Vdc max. Output : 2 Relays SPDT (2A, 250 Vac) (2A, 30Vdc). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz., 1 min. Approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 4035ISSMART ATEX series transmitters and convertersDin rail universal PC configurable Transmitter. Input : mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. Power supply 10...32Vdc (loop powered), reverse polarity protection, 60Vdc max. Intrinsically Safe version approved ATEX 94/9/EC. Protection mode : II 1 G Ex ia II C. (T5: -20 + 70 °C; T6: -20 + 55 °C)Datexel
DAT 4035IS/HTSMART ATEX series transmitters and convertersDin rail universal PC configurable Transmitter. Input : mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. Power supply 10...32Vdc (loop powered), reverse polarity protection, 60Vdc max. Intrinsically Safe version approved ATEX 94/9/EC. Protection mode : II 1 G Ex ia II C. (T4: -20 + 85 °C; T5: -20 + 70 °C; T6: -20 + 55 °C)Datexel
DAT 4235IS/ASMART ATEX series transmitters and convertersDin Rail universal PC configuration Signal Converter. Input : mV, V, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power supply 20...30Vdc. Reverse polarity protection : 60Vdc max. Output : 0/1...10V, 0/4...20mA. Galvanic insulation : power supply // input // output : 1500Vac, 50Hz., 1 min. Approved ATEX 94/9/CE Protection mode: II (1) G D [Ex ia] II C - [Ex ia D].Datexel
DAT 2015IS/HTSMART ATEX series transmitters and convertersNot insulated din rail PC configurable transmitter, universal input : mV, mA, Resistance, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power supply 10...32Vdc (loop powered). Reverse polarity protection 60Vdc max. Output : 4...20mA. intrinsically Safe version approved ATEX 94/9/EC. Protection mode : II 1 G Ex ia II C. (T4: -20 + 85 °C; T5: -20 + 70 °C; T6: -20 + 55 °C)Datexel
DAT 2015ISSMART ATEX series transmitters and convertersNot insulated din rail PC configurable transmitter, universal input : mV, mA, Resistance, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Power supply 10...32Vdc (loop powered). Reverse polarity protection 60Vdc max. Output : 4...20mA. intrinsically Safe version approved ATEX 94/9/EC. Protection mode : II 1 G Ex ia II C. (T5: -20 + 70 °C; T6: -20 + 55 °C)Datexel
DAT 4520SMART SERIES temperature and signal convertersDin Rail universal PC configuration Signal Converter. Input : mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), TC (CJC int./ext.) type : J,K,R,S,T,B,E,N. Output : 0/1...10V, 0/4...20mA (active or passive). Trip amplifier: 2 SPDT relays. Power supply 20...30Vdc, reverse polarity protection 60Vdc max. Galvanic insulation : input // power supply // output : 1500Vac, 50Hz., 1 min.Datexel
DAT 4135SMART SERIES temperature and signal convertersDin rail universal input PC configurable converter. Input: mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. Output (0/1...10 V) and current (0/4...20mA). Power supply 18...30Vdc. Reverse polarity protection, 60Vdc max.Datexel
DAT 4135/SELSMART SERIES temperature and signal convertersDin rail universal input PC configurable converter. Input: mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. Output (0/1...10 V) and current (0/4...20mA). Power supply 18...30Vdc. Reverse polarity protection, 60Vdc max.Datexel
DAT 4235SMART SERIES temperature and signal convertersDin rail universal input PC configurable converter. Input: mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. Output (0/1...10 V, -10V) and current (0/4...20mA, -20mA). Power supply 18...30Vdc, reverse polarity protection 60Vdc max. Galvanic insulation : power supply // output : 1500Vac, 50Hz., 1 min.Datexel
DAT 4035SMART SERIES temperature and signal convertersDin rail universal PC configurable Transmitter. Input : mV, mA, Ohm, RTD 2,3,4 wires (Pt100, Pt1000, Ni100, Ni1000), Potentiometer, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. Power supply 10...32Vdc (loop powered), reverse polarity protection, 60Vdc max.Datexel
DAT 4632/DSLIM SERIES signal Transmitters and ConvertersMathematical din rail converter. 2 Input channel V, mA. 2 output channel (0/1...10 V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz., 1 min. Power supply 18...30Vdc. Reverse polarity protection 60Vdc max.Datexel
DAT 4631/ASLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC splitter. 1 input channel: mV, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4631/BSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC splitter. 1 input channel: RTD (2,3 fili) : Pt100, Pt1000, Ni100, Ni1000 and Ohm. 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4631/CSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC splitter. 1 input channel: PTC: KTY81-210, KTY81-220, KTY84-130, KTY84-150; NTC : COSTER 10K, COSTER 1K; Potentiometer (Nominal Value Resistance < 50 Kohm). 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4631/DSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC splitter. 1 input channel: V, mA.. 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4540/RSLIM SERIES signal Transmitters and ConvertersDip switch and PC, Frequency to Voltage, Frequency to Current din rail converter. 1 input channel : Namur (DIN19234), TTL, PNP, TACHO, Voltage (programmable), Frequency. 2 outpu channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4540/TSLIM SERIES signal Transmitters and ConvertersDip switch and PC, Frequency to Voltage, Frequency to Current din rail converter. 1 input channel : Namur (DIN19234), TTL, PNP, TACHO, Voltage (programmable), Frequency. 2 outpu channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4532/DSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC converter. 2 input channel: V, mA.. 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4532/BSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC converter. 2 input channel: RTD (2,3 fili) : Pt100, Pt1000, Ni100, Ni1000 and Ohm. 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. Reverse protection polarity 60Vdc max.Datexel
DAT 4532/CSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC converter. 2 input channel: PTC: KTY81-210, KTY81-220, KTY84-130, KTY84-150; NTC : COSTER 10K, COSTER 1K; Potentiometer (Nominal Value Resistance < 50 Kohm). 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18 ... 30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4531/DSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC converter. 1 input channel: V, mA.. 1 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4532/ASLIM SERIES signal Transmitters and ConvertersDouble channel din rail configurable by dip switch and PC converter. 2 input channel: mV, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. 2 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18...30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4531/CSLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC converter. 1 input channel: PTC: KTY81-210, KTY81-220, KTY84-130, KTY84-150; NTC : COSTER 10K, COSTER 1K; Potentiometer (Nominal Value Resistance < 50 Kohm). 1 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18 ... 30Vdc. Reverse protection polarity 60Vdc max.Datexel
DAT 4531/ASLIM SERIES signal Transmitters and ConvertersDin rail configurable by dip switch and PC converter. 1 input channel: mV, TC (CJC int./ext.) type: J,K,R,S,T,B,E,N. 1 output channel (0/1...10V) and current (0/4...20mA). Galvanic insulation : power supply // input // output : 1500Vac, 50Hz. , 1 min. Power supply 18 ... 30Vdc. Reverse protection polarity 60Vdc max.Datexel
Loading...